Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters

Database
Language
Document Type
Year range
1.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.07.29.21261348

ABSTRACT

Objectives To calculate the observed rates of thrombosis and thrombocytopenia following vaccination against SARS-CoV-2, infection with SARS-CoV-2, and to compare them to background (expected) rates in the general population. Design Cohort study using routinely collected primary care records. Setting Routine practice in the United Kingdom. Participants Two mutually exclusive vaccinated cohorts included people vaccinated with either ChAdOx1 or BNT162b2 between 8 December 2020 and 6 March 2021. A third cohort consisted of people newly infected with SARS-Cov-2 identified by a first positive RT-PCR test between 1 September 2020 and 28 February 2021. The fourth general population cohort for background rates included those people with a visit between 1 January 2017 and 31 December 2019. In total, we included 1,868,767 ChAdOx1 and 1,661,139 BNT162b2 vaccinees, 299,311 people infected with SARS-CoV-2, and 2,290,537 people from the general population. Interventions First-dose of either ChAdOx1 or BNT162b2 Main outcome measures Outcomes included venous thrombosis, arterial thrombosis, thrombocytopenia, and thrombosis with thrombocytopenia. Outcome rates were estimated for recipients of the ChAdOx1 or BNT162b2 vaccines, for people infected with SARS-CoV-2, and background rates in the general population. Indirectly standardized incidence ratios (SIR) were estimated. Results We included 1,868,767 ChAdOx1 and 1,661,139 BNT162b2 vaccinees, 299,311 people infected with SARS-CoV-2, and 2,290,537 people from the general population for background rates. The SIRs for pulmonary embolism were 1.23 [95% CI, 1.09-1.39] after vaccination with ChAdOx1, 1.21 [1.07-1.36] after vaccination with BNT162b2, and 15.31 [14.08 to 16.65] for infection with SARS-CoV-2. The SIRs for thrombocytopenia after vaccination were 1.25 [1.19 to 1.31] for ChAdOx1 and 0.99 (0.94 to 1.04) for BNT162b2. Rates of deep vein thrombosis and arterial thrombosis were similar among those vaccinated and the general population. Conclusions ChAdOx1 and BNT162b2 had broadly similar safety profiles. Thrombosis rates after either vaccine were mostly similar to those of the general population. Rates of pulmonary embolism increased 1.2-fold after either vaccine and 15-fold with SARS-CoV-2 infection. Thrombocytopenia was more common among recipients of ChAdOx1 but not of BNT162b2.


Subject(s)
Pulmonary Embolism , Thrombocytopenia , Thrombosis , Hallucinations , COVID-19 , Venous Thrombosis
SELECTION OF CITATIONS
SEARCH DETAIL